Drug Delivery Devices
video
Drug Delivery Devices

Drug Delivery Devices

1 mL Automatic Injection Pen — precision engineered
Glass cartridge and needle assembly for automatic pen injectors. Designed for subcutaneous delivery of insulin, GLP-1 agonists, and growth hormone — with dose setting, one-click injection, and a fully concealed needle.

  • Fast Delievery
  • Quality Assurance
  • 24/7 Customer Service
  • iconFull Customization

Description

drug delivery devices

1 ml automatic injection pen

precision engineered

Glass cartridge and needle assembly for automatic pen injectors

subcutaneous delivery

Designed for subcutaneous delivery of insulin, GLP-1 agonists, and growth hormone - with dose setting, one-click injection

 

REQUEST SPECIFICATIONS

1 ml cartridge

 

one-click injection

 

ISO 15747 certified print

 

concealed need

 

01 dose setting

Clearly marked dial allows precise unit-by-unit dose selection. Tactile click feedback confirms each increment - reducing dosing error at the point of administration.

02 one-click injection

Single-button actuation delivers the full set dose in one motion. Consistent injection force regardless of formulation viscosity or user grip strength.

03 concealed needle

Needle is shielded before and after injection. Reduces needle anxiety, minimises accidental needlestick exposure, and simplifies safe disposal for daily self-administering patients.

glass cartridge include aluminum cap and rubber plug

 

Does this product fit your insulin cartridge?

The flat-top bottle on the left is compatible, while the threaded bottle on the right is not.

product-1024-454
product-512-163
01

3 ml glass cartridge dimensions 

 

02

1.5 ml glass cartridge dimensions

product-512-167
product-512-365
03

drug delivery devices

04

automatic pen injection simply dial and dose

 

product-512-365

 

ISO 15747-Compliant Custom Printing

Cartridge and pen body printing is produced to ISO 15747 pharmaceutical packaging standards. Custom legends, dosage scales, brand names, and regulatory text can be applied in single or multicolour. Printed surfaces maintain full legibility across the product's intended shelf life.

 

 

pharmaceutical packaging print standard

 

 

alcohol-wipe resistant

Print survives repeated 70% IPA wipe-down without smearing, fading, or adhesion failure - meeting clinical surface-disinfection protocols

high temperature & humidity stable

Colour and legibility are retained after accelerated ageing in high-temp, high-humidity environments - compliant with ICH Q1A storage stress conditions.

no fade, no bleed

Ink system is formulated specifically for glass and polymer pen surfaces. No migration into the drug product; no visible degradation in use.

 

 

applications

built for drugs that require
 

regular subcutaneous injection

insulin

Rapid, intermediate, and long-acting insulin formulations. Compatible with standard U-100 and U-200 concentrations. Daily or multiple-daily-dose regimens.

GLP-1 receptor agonists

Semaglutide, liraglutide, dulaglutide, and related biologics for type 2 diabetes and obesity management. Weekly or daily subcutaneous dosing schedules.

growth hormone

Recombinant human growth hormone (rhGH) therapy for paediatric and adult indications. Precision low-volume dosing in microgram increments.

other biologics

Any viscous or protein-based therapeutic requiring consistent subcutaneous delivery - including monoclonal antibodies, fertility hormones, and anticoagulants.

self-administration

Concealed needle and one-click mechanism are specifically designed to reduce the cognitive and physical barrier for patients self-injecting at home.

clinical & institutional

ISO-compliant labelling and sterile assembly meet institutional pharmacy and hospital formulary requirements worldwide.

 

custom specifications and OEM printing available
 
 

We supply glass cartridges, needle assemblies, and complete pen components with custom printed legends to your regulatory and branding requirements. Contact us to discuss volume, print specifications, or to request a sample kit.

 

CONTACT US

REQUEST A SAMPLE

 why won't the screw rod move forward?

+

-

The screw rod will only advance after the cartridge holder is correctly installed. Once the cartridge is properly seated, the screw rod moves forward during injection and will not retract during use.

 

1. Remove the cartridge holder and check that the 3 mL cartridge is fully inserted.

2. Re-attach the cartridge holder, aligning it straight with the pen body.

3. Rotate to tighten until secure, then attempt to advance the screw rod again.

 what should I do if the cartridge holder won't attach to the pen?

+

-

This usually means the cartridge is not fully seated inside the cartridge holder. Follow these steps:

 

1. Check that the 3 mL cartridge is pushed all the way into the cartridge holder - no part of the cartridge should protrude.

2. Hold the cartridge holder and pen body in a straight line before attempting to join them.

3. Rotate the pen body and cartridge holder together to tighten. Do not force - if resistance is felt, realign and try again.

 why is the injection priming step important?

+

-

Priming removes air from the needle and confirms that the pen is working correctly before you inject. Skipping this step may result in an inaccurate dose - you could receive less medication than intended.

Always prime before each new cartridge and whenever the pen has not been used for an extended period. A small drop of liquid appearing at the needle tip confirms the pen is ready.

 

 Clears air bubbles from the cartridge and needle

 Confirms the screw rod is in contact with the cartridge plunger

 Verifies the needle is correctly attached and not blocked

 why do I need to prime multiple times after inserting a new cartridge?

+

-

When a new cartridge is loaded, there may be a gap between the screw rod and the cartridge plunger. Multiple priming steps allow the screw rod to travel forward until it makes firm contact with the plunger - at which point medication will flow.

 

 no liquid appears at the needle tip after priming - what should I check?

+

-

1. Check the needle: ensure it is screwed on tightly and the inner needle seal has been punctured on attachment.

2. Check cartridge level: confirm the cartridge still contains medication - an empty cartridge cannot be primed.

3. Try a new needle: the needle may be blocked. Replace with a fresh needle and prime again.

4. Repeat priming: on a new cartridge, up to 6 priming attempts may be needed before the screw rod fully contacts the plunger.

 

 

 

 

Hot Tags: drug delivery devices, China drug delivery devices manufacturers, suppliers, Disposable Pen Injector, Dosage Adjustable Disposable Injector Pen, Disposable Pen Injector for 3ML Cartridge, High Precision Of Semaglutide Disposable Injection Pen, 3ml Cartridge Insulin Disposable Pen Injector, 3ml Pre filled Insulin Disposable Pen Injector